HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts below to properly match your hydraulic system to the capstan
performance. The charts consist of: (1) first layer line pull (LB) vs. working pressure (PSI), (2)
first layer line speed (FPM) vs. flow (GPM), and (3) relief valve setting (PSI) vs. flow (GPM). A
motor spool directional control valve is required.
*CAUTION: DO NOT EXCEED 20 G.P.M. IF EXCEEDED, MOTOR AND WINCH MAY BE DAMAGED
TYPICAL LAYOUT
SYSTEM REQUIREMENTS:
2500 PSI RELIEF VALVE SETTING
20 GPM FLOW RATE*
10 MICRON NOMINAL FILTRATION
3
PERFORMANCE WITH 9.8 CU. IN. HYDRAULIC MOTOR
PERFORMANCE CHARTS